Hardware installation, Connect the power and ground – Comtrol ES8510-XT User Manual

Page 9

Advertising
background image

RocketLinx ES8510 and ES8510-XT User Guide: 2000513 Rev. H

Hardware Installation - 9

Hardware Installation

You can use the following subsections to install the RocketLinx ES8510:

Connect the Power and Ground

Connect the Digital Input s and Relay Outputs

on Page 10

Mount the ES8510

on Page 11

Connect the Ethernet Ports

on Page 12

Connect SFP Transceivers (Combo Ports 8-10)

on Page 13

LED Descriptions

on Page 13

Panel Layout

on Page 14

Reset Button

on Page 14

Connect the Power and Ground

You can use the following procedure to connect power and the ground to the ES8510.

1.

Connect the DC power inputs.

a.

Insert positive and negative wires (12-24AWG) into the PW+ and PW- contacts.

Note: Power should be disconnected from the power supply before connecting it to the switch.

Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.

AC Power Input

AC Power Input

Power Supply

12-48

VDC

(UL Listed)

Power Supply

12-48

VDC

(UL Listed)

V-

V+

V-

V+

12 - 24AWG Wire

12 - 24AWG Wire

Wiring Power Supplies

Positive and negative power system inputs are both accepted, but PW1 and
PW2 must be applied in the same mode.