AT Commands Reference Manual

Conexant

100722B

3-94

+PQC - V.92 Phase 1 and Phase 2 Control

This command controls the global enabling or disabling of the V.92 shortened Phase 1
and Phase 2 startup procedures. This command is used in conjunction with the +PSS
command.

Syntax

+PQC=<value>

Defined Values

<value>

Decimal number corresponding to the selected setting.

0

Enable Short Phase 1 and Short Phase 2.
(Default.)

1

Enable Short Phase 1 only.

2

Not supported.

3

Disable Short Phase 1 and Short Phase 2.

Result Codes

OK

0, 1, or 3 in V.92 Mode (+MS=V.92)

ERROR

Otherwise

Reporting Selected Values

Command: +PQC?

Response:

+PQC: <value>

Example:

+PQC: 0

Reporting Supported Range of Parameter Values

Command: +PQC=?

Response:

+PQC: (<value> range)

Example:

+PQC: (0,1,3)