AT Commands Reference Manual

Conexant

100722B

2-6

The following syntax is used for actions that have one subparameter:

+<name>[=<value>]

The following syntax is used for actions that have two or more subparameters:

+<name>[=<compound_value>]

For actions that accept subparameters, if all subparameters are defined as being optional,
and the default values for all subparameters are satisfactory, the data terminal equipment
(DTE) may use the first syntax above (i.e., omit the "=" from the action execution
command as well as all of the subparameter value string).

If all other relevant criteria are met (e.g., the modem is in the proper state), the command
is executed with any indicated subparameters. If <name> is not recognized, the modem
issues the ERROR result code and terminates processing of the command line. An
ERROR is also generated if a subparameter is specified for an action that does not accept
subparameters, if too many subparameters are specified, if a mandatory subparameter is
not specified, if a value is specified of the wrong type, or if a value is specified that is not
within the supported range.

Action Test Command Syntax

The DTE may test if an action command is implemented in the modem by using the
syntax:

+<name>=?

If the modem does not recognize the indicated name, it returns an ERROR result code
and terminates processing of the command line. If the modem does recognize the action
name, it returns an OK result code. If the named action accepts one or more
subparameters, the modem sends an information text response to the DTE, prior to the
OK result code, specifying the values supported by the modem for each such
subparameter, and possibly additional information. The format of this information text is
defined for each action command.

2.4.4

Parameter Commands

Parameter Types

Parameters may be defined as "read-only" or "read-write". "Read-only" parameters are
used to provide status or identifying information to the DTE, but cannot be set by the
DTE; attempting to set their value is an error. In some cases (specified in the description
of the individual parameter), the modem may ignore attempts to set the value of such
parameters rather than respond with an ERROR result code, if the continued correct
operation of the interface between the modem and DTE will not be affected by such
action. Read-only parameters may be read and tested.

"Read-write" parameters may be set by the DTE, to store a value or values for later use.
Read-write parameters may be set, read, and tested.

Parameters may take either a single value, or multiple (compound) values. Each value
may be either numeric or string; the definition of the parameter will specify the type of
value for each subparameter. Attempting to store a string value in a numeric parameter,
or a numeric value in a string parameter, is an error.

Advertising