background image

AT Commands Reference Manual

100722B

Conexant

5-21

5.5.6

+FPTS= - Page Transfer Status

Write Syntax:

+FPTS=<ppr>

Valid values:

1, 2, 3, 4, 5

Default value:

0

The +FPTS parameter contains a value representing the post page response, including
copy quality and related end-of-page status. These values correspond to post page
response messages defined in T.30. The receiving DCE sets this parameter after it
receives a page of Phase C data. The transmitting DCE sets this parameter with the status
reported by the receiving station. The DTE may inspect or modify this parameter.

The set of <ppr> values is defined in Table 5-4. These values are also reported in the
+FPTS response to the +FDR command.

5.5.7

+FCQ - Copy Quality Checking

Write syntax:

+FCQ=<value>

Valid values:

0

Default value:

0

This parameter controls Copy Quality checking by a receiving facsimile DCE.

The DCE returns +FCQ=0 which indicates the DCE does no quality checking. The DCE
will generate Copy Quality OK (MCF) responses to complete pages, and set +FPTS=1.

5.5.8

+FPHCTO - DTE Phase C Response Time-out

Write syntax:

+FPHCTO=<value>

Valid values:

0 - 255, 100 millisecond units.

Default value:

30

The +FPHCTO command determines how long the DCE will wait for a command after
reaching the end of data when transmitting in Phase C. When this time-out is reached, the
DCE assumes there are no more pages and no documents to send. It then sends the T.30
EOP response to the remote device.

5.5.9

+FAXERR - T.30 Session Error Report

Read syntax:

+FAXERR= <table value>, read only

Valid values:

0 - 255, see Table 5-5 for meaning

This read-only parameter indicates the cause of the hangup. Table 5-5 shows the valid
values for this parameter as well as the meaning of the each value. +FAXERR is set by
the DCE at the conclusion of a fax session. The DCE resets +FAXERR to 0 at the
beginning of Phase A off-hook time.