Comtrol AT Command Set Rev A User Manual
Page 188
AT Commands Reference Manual
Conexant
100722B
5-16
5.4.6
+FCSI: - Report the Called Station ID
Syntax:
+FCSI: “<CSI ID string>” Called Station ID
This response reports the received called station ID string, if any. This message is
generated in execution of Originate, Answer, +FDT, or +FDR commands.
5.4.7
+FPTS: - Receive Page Transfer Status
Syntax:
+FPTS:<ppr>, <lc> [,<blc>, <cblc>]
The +FPTS:<ppr> is generated by the DCE at the end of Phase C data reception in
execution of a +FDR command.
The <ppr> is generated by the DCE; it depends on the DCE capabilities at T.4 error
checking. See Table 5-4 for <ppr> values.
The receiving DCE will count the lines. These values are;
<lc> = line count
<blc = bad line count
<cblc> = <consecutive bad line count
A receiving DTE may inspect <ppr> and write a modified value into the +FPTS
parameter. The DCE will hold the corresponding Post Page Response message until
released by a +FDR command from the DTE.
5.4.8
+FET: - Post Page Message Response
Syntax:
+FET:<ppm>
The +FET:<post page message> response is generated by a receiving DCE after the end
of Phase C reception on receipt of the post-page message from the transmitting station.
The +FET:<ppm> response is generated in execution of a +FDR command. The <ppm>
codes respond to the T.30 post page messages (Table 5-3).
5.4.9
+FPTS: - Transmit Page Transfer Status
Syntax:
+FPTS:<ppr>
The +FPTS: response reports a <ppr> number representing the copy quality and related
post-page message responses received from the remote DCE. The valid <ppr> values are
defined in Table 5-4.
The +FPTS:<ppr> response is generated in execution of a +FET=<ppm> command.