AT Commands Reference Manual

100722B

Conexant

5-9

<CAN> - Escape from Transmission

The DCE may request the DTE to halt Phase C transmission, by sending a cancel
<CAN> character (024) to the DTE. In this case, the DTE should terminate Phase C
transmission, issue <CAN>, and wait for the OK response code from the DCE.

Table 5-2. T.30 Session Subparameter Codes

Label

Function

Value

Description

VR

Vertical Resolution

0

Normal, 98 lpi

1

Fine, 196 lpi

BR

Bit Rate (See Note 1)

+FDCS (originate)

+FDIS (answer)

0

2400 bps/V.27 ter

V.27 ter (2400 only)

1

4800 bps/V.27 ter

V.27 ter

2

7200 bps/V.29

V.29, V.27 ter

3

9600 bps /V.29 or V.17

V.29, V.27 ter

4

12000 bps/V.33 or V.17

V.17, V.33, V.29, V.27 ter

5

14400 bps/V.33 or V.17

V.17, V.33, V.29, V.27 ter

WD

Page Width

0

1728 pixels in 215 mm

1

2048 pixels in 255 mm

2

2432 pixels in 303 mm

3*

1216 pixels in 151 mm

4*

864 pixels in 107 mm

LN

Page Length

0

A4, 297 mm

1

B4, 364 mm

2

unlimited length

DF

Data Compression
Format

0

1-D modified Huffman

1*

2-D modified Read

2*

2-D uncompressed mode

3*

2-D modified modified Read

EC

Error Correction

0

Disable ECM

(Annex A/T.30)

1*

Enable ECM, 64 bytes/frame

2*

Enable ECM, 256
bytes/frame

BF

Binary File Transfer

0

Disable BFT

1*

Enable BFT

ST

Scan Time/Line

VR = normal

VR = fine

0

0 ms

0 ms

1

5 ms

5 ms

2

10 ms

5 ms

3

10 ms

10 ms

4

20 ms

10 ms

5

20 ms

20 ms

6

40 ms

20 ms

7

40 ms

40 ms

Notes:

1. CCITT T.30 does not provide for the answering station to specify all speeds exactly using the DIS frame.

Implementation of some BR codes (e.g., code 2) by an answering DCE is manufacturer specific.

* Not supported.