IC Realtime 4 Channel Forensic Network Video Recorder User Manual

Page 25

Advertising
background image

16

Please refer to the following sheet for alarm input and output connection.

There are two alarm input types for you to select: normal open (NO) and normal close (NC).

1. Alarm input
a. Please make sure alarm input mode is grounding alarm input.
b. Grounding signal is needed for alarm input.
c. Alarm input needs the low level voltage signal.
d. Alarm input mode can be either NC (normal Open) or NO (Normal Close)
e. When you are connecting two NVRs or you are connecting one NVR and one other device,
please use a relay to separate them,
2. Alarm output
The alarm output port should not be connected to high power load directly (It shall be less than
1A) to avoid high current which may result in relay damage. Please use the co contactor to
realize the connection between the alarm output port and the load.
3. How to connect PTZ decoder
a. Ensure the decoder has the same grounding with NVR, otherwise you may not control the PTZ.
Shielded twisted wire is recommended and the shielded layer is used to connect to the grounding.
b. Avoid high voltage. Ensure proper wiring and some thunder protection measures.
c. For too long signal wires, 120Ω should be parallel connected between A, B lines on the far end
to reduce reflection and guarantee the signal quality.
d. “485 A, B” of NVR cannot parallel connect with “485 port” of other device.
e. The voltage between of A,B lines of the decoder should be less than 5v.
4. Please make sure the front-end device has soundly earthed.
Improper grounding may result in chip damage.

3.8.1 Alarm Input and Output Details

You can refer to the following sheet

X

for alarm input and output information.

The series product interface is shown as below. See Figure 3-1.

Figure 3-1

Please refer to the following sheet and Figure 3-1 for detailed information.

1,2,3,4,

ALARM 1 to ALARM 4. The alarm becomes active in low voltage.

NO1 C1,NO2 C2

There are two groups of normal open activation output (on/off
button)

Earth cable.

485 A/B

485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.


3.8.2 Alarm Input Port

Please refer to the following sheet for more information.

AB cable
connection