Operating parameters

You can use the following commands to configure and display the mode of operation for the
switch and display key parameters. The rules of syntax and output examples are all set out in
detail in the Reference Guide for the Avaya C360 Converged Stackable Switch, 10-300506.

Network Time Acquiring Protocols Parameter Configuration

The C360 can acquire the time from a Network Time Server. C360 supports the SNTP Protocol
(RFC 958) over UDP port 123 or TIME protocol over UDP port 37. Use the CLI commands
briefly described below for configuring and display time information and acquiring parameters.
The rules of syntax and output examples are all set out in detail in the Reference Guide for the
Avaya C360 Converged Stackable Switch,
10-300506.

Table 25: Operating Parameter CLI Commands

In order to...

Use the following command...

Configure the basic mode of
operation of a module to either
Layer 2 or Router

set device-mode

Display the mode of operation

show device-mode

Display system parameters

show system

Display module information for
all modules within the stack

show module

In order to...

Use the following command...

Restore the time zone to its
default, UTC.

clear timezone

Configure the time zone for the
system

set timezone

Configure the time protocol for
use in the system

set time protocol

Enable or disable the time client

set time client

Configure the network time
server IP address

set time server

Display the current time

show time

1 of 2