ADLINK PCI-8102 User Manual

Page 162

Advertising
background image

Function Library

151

PCI-8102

@ Argument

AxisNo: Axis number of Target Axis.card_idPhysical axisAxisNo

on_off: ON-OFF state of SVON signal

pcs_logic: PCS signal input logic

clr_mode: Clear action mode.

X

clr_mode = 0 , Clear on the falling edge (default)

X

clr_mode = 1 , Clear on the rising edge

X

clr_mode = 2 , Clear on a LOW level

X

clr_mode = 3 , Clear on a HIGH level

inp_enable: INP function enabled/disabled

X

inp_enable = 0, Disabled (default)

X

inp_enable = 1, Enabled

inp_logic: Set the active logic for the INP signal

card_id

Physical axis

AxisNo

0

0

0

1

1

1

0

2

1

3

2

0

4

1

Value

Meaning

0

ON

1

OFF

Value

Meaning

0

Negative logic

1

Positive logic

Value

Meaning

0

Negative logic

Advertising