ADLINK PCI-8102 User Manual
Page 172
Function Library
161
PCI-8102
B_8102_set_general_counter(ByVal AxisNo As
Integer, ByVal CntSrc As Integer, ByVal
CntValue As Double) As Integer
B_8102_get_general_counter(ByVal AxisNo As
Integer, ByRef Pos As Double) As Integer
B_8102_reset_target_pos(ByVal AxisNo As Integer,
ByVal Pos As Double) As Integer
B_8102_get_target_pos(ByVal AxisNo As Integer,
ByRef Pos As Double) As Integer
B_8102_set_res_distance(ByVal AxisNo As Integer,
ByVal Res_Distance As Double) As Integer
B_8102_get_res_distance(ByVal AxisNo As Integer,
ByRef Res_Distance As Double) As Integer
@ Argument
AxisNo: Axis number of Target Axis.
Pos, *Pos: Feedback position counter value, (_8102_get/
set_position)
range: -134217728~134217727
command, *command: Command position counter value,
range: -134217728~134217727
*error: Position error counter value,
range: -32768~32767
CntSrc: general counter source
card_id
Physical axis
AxisNo
0
0
0
1
1
1
0
2
1
3
2
0
4
1
…
Value
Meaning
0
Command pulse
1
EA/EB