RMC70/150 and RMCTools User Manual

AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data

Type

Internal
I
EC

Address

Internal

Data

Type

Access

Register Name

F31:0

15873

D15872 REAL

%MD31.0 UDINT Read/Write Current Plot Layout

This register indicates

the current plot

allocation.

Bit Description
0-7 Plots (1-8)
8-

15

Sample Sets per

Plot (1-16)

16-

23

Reserved

F31:1

15875

D15874 REAL

%MD31.1 UDINT Read Only Maximum Plots (8)

This read-only value

indicates how many

plots can be defined

at once.

F31:2

15877

D15876 REAL

%MD31.2 UDINT Read Only Maximum Samples

(16)
This read-only value

indicates how many

samples sets can be

captured

simultaneously per

plot.

F31:3

15879

D15878 REAL

%MD31.3 UDINT Read Only Maximum Samples at

Once (128)
This read-only value

indicates how many

total different

samples can be

allocated across all

plots.

F31:4

15881

D15880 REAL

%MD31.4 UDINT Read Only Maximum Elements

RMC75S/P: 32,768
RMC75E: 12,583,912
Note: Prior to 2.00

firmware, the

RMC75E is limited to

32,768 elements.

Prior to 1.02 Loader,

the RMC75E is limited

to 4,194,304.
This read-only value

indicates how many

total data points can

be captured. This is

spread out among the

number of allocated

plots and samples per

1070

Delta Computer Systems, Inc.

Advertising