Count unwind, Count offset, E count – Delta RMC151 User Manual

Page 916: Unwind, E count unwind, Count unwind), E count offset, R count offset

Advertising
background image

RMC70/150 and RMCTools User Manual

Changing this Parameter
Because this parameter affects motion, the axis must be disabled or in Direct Output

before writing to this parameter. The Enabled and Direct Output Status Bits indicate these

states of the axis. When changing this parameter from RMCTools, the software will

automatically do this for you. This may cause a halt on the axis, which is expected.

9.2.2.2.11. Count Unwind

Type: Axis Parameter Register

RMC70 Address: %MDn.13, where n = 12 + the axis number

RMC150 Address: %MDn.13, where n = 24 + the axis number

System Tag: _Axis[n].CntUnwind, where n is the axis number

How to Find: Axes Parameters Pane, Setup tab: Primary Control Setup

Data Type: DINT

Units: pu

Range: > 0

Default Value: 1024

Description

This parameter is used on rotary position axes together with the Position Unwind, Position

Offset and Count Offset parameters to convert the transducer feedback Counts to an

Actual Position.
The Count Unwind parameter defines the range of feedback Counts that maps to the

Position Unwind. As the encoder rotates through the range of counts de fined by the

Count Unwind, the Actual Position will go through the entire range of numbers specified

by the Position Unwind.
For axes configured as Rotary Absolute, the Count Unwind parameter must be a power of

2, such as 1024, 8192, etc.
Example:

Consider an SSI Rotary Absolute encoder with 8192 counts per revolution. The user

wants to set it up so that it goes from 0 to 360 on one revolution. To do this, the Count

Unwind must be set to 8192, and the Position Unwind must be set to 360.
Valid Range
The valid range of the Count Unwind parameter is limited for certain feedback types.

SSI Feedback on Absolute Rotary Axes

The Count Unwind parameter must be less than or equal to 2

N

, where N is the SSI

Data Bits. For example, for a 13-bit SSI encoder, the SSI Data Bits would be set to 13,

and the maximum Count Unwind value would be 2

13

, which is 8192.

Resolver Feedback on Absolute Rotary Axes

The maximum value of the Count Unwind parameter for resolver feedback is 65536.

Changing this Parameter
Because this parameter affects motion, the axis must be disabled or in Direct Output

before writing to this parameter. The Enabled and Direct Output Status Bits indicate these

states of the axis. When changing this parameter from RMCTools, the software will

automatically do this for you. This may cause a halt on the axis, which is expected.

9.2.2.2.12. Count Offset

896

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: