Ssi module, Ssi (s) module (rmc150), 150 ssi module – Delta RMC151 User Manual

Page 678: Ssi (s), 150 ssi, Module

Advertising
background image

RMC70/150 and RMCTools User Manual

Overvoltage Protection Outputs are protected by clamp diodes

LEDS

Axis 0 LED
Axis LED applies to the Drive 0 output or feedback input 0 as described below:

1. If Drive 0 is assigned to an axis that has an input (i.e. isn't output-only), then that

axis will own the Axis 0 LED.

2. Otherwise, if a reference input axis (no output) uses input 0, then that axis will own

the Axis 0 LED.

3. Otherwise, if Drive 0 is assigned to an output-only axis, then that axis will own Axis 0

LED.

Axis 1 LED

Axis 1 LED applies to the Drive 1 output or feedback input 1 as described below:

1. If Drive 1 is assigned to an axis that has an input (i.e. isn't output-only), then that

axis will own the Axis 1 LED.

2. Otherwise, if a reference input axis (no output) uses input 1, then that axis will own

the Axis 1 LED.

3. Otherwise, if Drive 1 is assigned to an output-only axis, then that axis will own the

Axis 1 LED.

LED Colors

State

Description

Steady

Off

No power or the output/input is not assigned to an axis.

Steady

Green

The axis is either in closed loop control or is a reference axis. The axis is

not halted.

Flashing

Green

The output is in open loop and the axis is not halted (not possible for

reference axes).

Flashing

Red

A Closed Loop Halt or External Halt has occurred because an error bit is set

(not possible for reference axes). The LED will not turn red due to a halt

caused by a halt command.

Steady

Red

An Open Loop Halt or Direct Output Halt has occurred because an error bit

is set (for reference axes, any halt has occurred). The LED will not turn red

due to a halt caused by a halt command.

7.3.6. SSI Module

7.3.6.1. SSI (S) Module (RMC150)

Important!

The SSI module requires RS-422 (5V differential) SSI inputs. It does not support single-ended

SSI inputs or higher voltage inputs.

The SSI module for the RMC150 interfaces to feedback devices using the Synchronous Serial

Interface (SSI) standard. Many types of transducers are available with SSI, including

magnetostrictive displacement transducers (MDTs), absolute encoders, and laser measuring

devices. SSI has a number of advantages over other transducer interfaces. First, it offers

higher noise immunity. Second, it gives absolute positions. Third, it supports a wide variety of