Maximum force (simulator), Maximum, Force – Delta RMC151 User Manual

Page 969: E maximum force

Advertising
background image

9 Register Reference

Type: Axis Parameter Register

RMC70 Address: %MDn.125, where n = 12 + the axis number

RMC150 Address: %MDn.125, where n = 24 + the axis number

System Tag: _Axis[n].SimWeight, where n is the axis number

How to Find: Axes Parameters Pane, All tab: Simulate

Data Type: REAL

Units: lb

Range: >0

Default Value: 1000

Description

The simulator weight parameter is the weight of the mass that the system is moving. This

weight is used when calculating the acceleration forces of the simulator.

Changing this Parameter

For best results, always change this parameter only from Axis Tools. If the axis is in

Simulate mode, and this parameter is changed, simulate model will be suspended until

the last simulate mode parameter register (Max Compression [Fx:127]) has been

updated. At this point, the new simulator model will be calculated and the simulator

model will be activated. When the simulator model is suspended, the Actual Position will

not move.
Certain simulator settings may result in an invalid model. If this occurs, change your

settings. See the Simulating Motion topic for more details.

9.2.2.3.10. Maximum Force (Simulator)

Type: Axis Parameter Register

RMC70 Address: %MDn.126, where n = 12 + the axis number

RMC150 Address: %MDn.126, where n = 24 + the axis number

System Tag: _Axis[n].SimMaxForce, where n is the axis number

How to Find: Axes Parameters Pane, All tab: Simulate

Data Type: REAL

Units: lb

Range: >0

Default Value: 10000

Description

This parameter specifies the maximum force of the system. The simulator simulates the

force it takes to accelerate and move the system (based on the Weight parameter) and

also simulates the spring force at the Positive Physical Limit and Negative Physical Limit.
The maximum force will limit the maximum acceleration of the axis. It will also affect the

max speed of the axis, similarly to a hydraulic system.
At the Positive and Negative Physical Limits, the simulator simulates a spring force that

extends outside the limit by the distance specified by the Maximum Compression

parameter. The Maximum Force specifies the max force at the max compression. The

spring force increases linearly from zero at the limit to the max force at the max

compression. This is useful for simulating pressure or force control.

deltamotion.com

949

Advertising
This manual is related to the following products: