Target pressure/force, Target pressure/force rate, Cycles (pressure or force) – Delta RMC151 User Manual

Page 902: Cycles (pressure/force), E target pressure/force, Target, Pressure/force, E target

Advertising
background image

RMC70/150 and RMCTools User Manual

The Command Pressure or Force is the requested pressure or force. For Pressure or Force

Limit, this will hold the requested Pressure/Force Limit value.

9.2.1.7.9. Target Pressure/Force

Type: Axis Status Register

RMC70 Address: %MDn.60, where n = 8 + the axis number

RMC150 Address: %MDn.60, where n = 8 + the axis number

System Tag: Pressure Input: _Axis[n].TarPrs, where n is the axis number

Force Input: _Axis[n].TarFrc, where n is the axis number

How to Find: Axes Status Registers Pane, Basic tab

Data Type: REAL

Units: Pr or Fr

Description

In Pressure/Force control, the Target Pressure/Force is the instantaneous desired

Pressure/Force value for the axis.
In Pressure/Force Limit, the Target Pressure/Force is the pressure/force value that should

not be exceeded. The control algorithm will try to limit the motion such that the Actual

Pressure or Force does not exceed the Target Pressure/Force.
The Target Pressure/Force is calculated every loop by the target generator of the RMC.

When the axis is not in Pressure/Force Control or Pressure/Force Limit, the Target

Pressure/Force can still be ramped up or down, but will have no effect on control.
See Pressure/Force Control Overview for more details.

9.2.1.7.10. Target Pressure/Force Rate

Type: Axis Status Register

RMC70

Address:

%MDn.63, where n = 8 + the axis number

RMC150

Address:

%MDn.63, where n = 8 + the axis number

System Tag: Pressure Input: _Axis[n].TarPrsRate, where n is the axis number

Force Input: _Axis[n].TarFrcRate, where n is the axis number

How to Find: Axes Status Registers Pane, All tab: Feedback or Pressure/Force/Accel

Feedback

Data Type: REAL

Units: Pr/s or Fr/s

Description

Target Pressure/Force Rate is the rate of change of the Target Pressure/Force. The Target

Pressure/Force Rate is calculated every loop by the target generator of the RMC.

9.2.1.7.11. Cycles (Pressure or Force)

882

Delta Computer Systems, Inc.

Advertising