System, Command: arm home (50), Arm registration (52) – Delta RMC151 User Manual

Page 845: Arm home (50), E arm home (50), N arm home (50)

Advertising
background image

8 Command Reference

Note: Delta does not recommend using this command. From a PLC, you can write to any

register directly without needing to send this command. In a user program, use the Expression

(113) command to write directly to registers.


This command writes the value specified by the Value parameter into the address

specified by the Address parameter.
This command is not intended to be used in user programs. Use the Expression (113)

command instead. For example, the following expression will write a value of 12 to the

variable MyVariable:

Notice that this command is not necessary for indirect addressing in expressions, as the

REG_REAL(file, elem) and related functions are the preferred method of indirect

addressing.

Specifying a Register Address

When issuing this command from anywhere other than RMCTools, the addresses in the

Address command parameter must be entered as an integer value.
RMC addresses are represented in IEC format as:

%MDfile.element, where file = file number, and element = element number.

Use the following equation to convert a register address to integer format, N:

N = file * 4096 + element


Example:
Register address %MD8.33 is 8*4096 + 33 = 32801.

8.7. System

8.7.1. Command: Arm Home (50)

Supported Axes: Quadrature, SSI, Resolver

Firmware Requirement: 1.45 or newer

See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Home Position (position-units)

any

2 Trigger Type

#

Name

Available on

RMC70

RMC150

0

H Rising

QAx, Q1,

SSI*

Quad, UI/O

Integers 0 to

7

deltamotion.com

825

Advertising
This manual is related to the following products: