Pressure/force feed forward, Ee pressure/force feed forward – Delta RMC151 User Manual

Page 997

Advertising
background image

9 Register Reference

In Pressure/Force I-PD, the Pressure/Force Differential Gain adjusts the Control Output

based on the change in the Actual Pressure/Force Rate. The Pressure/Force I-PD is used

in pressure/force limit on dual-loop axes with I-PD Position or Velocity Control.

Mathematical Definition

Pressure/Force PID

D

n

= (PR

Target

n - PR

Actual

n) x K

D

Pressure/Force I-PD

D

n

= (PR

Actual

n - PR

Actual

n-1) x K

D

where

D

n

= Pressure/Force Differential Term at sample n [% of maximum Control Output]

PR = Pressure or Force Rate [Pr/sec or Fr/sec]
K

P

= Pressure/Force Proportional Gain [%/(Pr/sec) or %/(Fr/sec)]

The Pressure/Force Differential Gain units are: percent of the maximum Control Output

per pressure or force units per second. The maximum Control Output is 10V, but can be

changed using the Output Scale parameter.

9.2.2.5.6. Pressure/Force Feed Forward

Type: Axis Parameter Register

RMC70 Address: Primary Control Axis: %MDn.64, where n = 12 + the axis number

Secondary Control Axis: %MDn.84, where n = 12 + the axis

number

RMC150

Address:

Primary Control Axis: %MDn.64, where n = 24 + the axis number
Secondary Control Axis: %MDn.84, where n = 24 + the axis

number

System Tag: Pressure Axis: _Axis[n].PrsFFwd, where n is the axis number

Force Axis: _Axis[n].FrcFFwd, where n is the axis number

How to Find: Axes Parameters Pane, Tune tab: Pressure/Force Tuning

Data Type: REAL

Units: %/(Pr) or %/(Fr)

Range: ≥ 0

Default Value: 0

Description

The Pressure/Force Feed Forward gives extra Control Output proportional to the Target

Pressure or Target Force. This gain is useful on systems that require a large amount of

drive to hold pressure or force, such as when a large flow is required to hold pressure or

force.
The Pressure/Force Feed Forward Term is the portion of the Control Output resulting from

this gain.

Advanced: Pressure/Force I-PD
In pressure/force I-PD, the Pressure/Force Feed Forward will not be applied. The

Pressure/Force I-PD is used in pressure/force limit on dual-loop axes with I-PD position

control or I-PD velocity control.

deltamotion.com

977

Advertising