Command: enter pressure/force control (auto) (44), Enter pressure/force control (auto) (44) – Delta RMC151 User Manual

Page 812

Advertising
background image

RMC70/150 and RMCTools User Manual

This bit indicates that pressure/force limit is enabled and the axis is limiting the

pressure/force. If an axis is in pressure or force control, pressure/force limit will not be

active and this bit will not be set.
Pressure/Force Target Generator Bits

The Pressure/Force Target Generator bits in the Status Bits register indicate which

portion of the move the axis is currently in. These bits are useful when programming

complex motion sequences.
Pressure/Force Target Generator Done bit
This bit indicates that the Target Pressure/Force has reached the Requested

Pressure/Force. If the ramp is interrupted, e.g. due to a halt, the done bit will not be

set because the commanded motion was not completed. Notice that this bit does not

indicate whether the Actual Pressure/Force has reached the Requested

Pressure/Force.
Pressure/Force Target Generator State A and B bits
B

A Description

0

0

Pressure/Force is stopped (done)

0

1

Pressure/Force is increasing

1

0

Reserved

1

1

Pressure/Force is decreasing

8.5.1.6. Command: Enter Pressure/Force Control (Auto) (44)

Supported Axes: Pressure/Force Control Axes

Firmware Requirement: 2.50 or newer

Hardware Limitations: RMC75S: versions 2.1D or newer only

RMC75P: versions 2.1E or newer only
RMC75E: No limitations
RMC150E: No limitations


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Requested Pressure/Force (Pr or Fr)

any

2 Ramp Type

Linear (0)

S-curve (1)

A valid integer as

described

3 Integrator Preload (%)

-100% to 100%

Description

This command enters pressure or force control and then ramps the pressure or force to

the Requested Pressure/Force in the manner specified by the Ramp Type. The rate of

the ramp is automatically determined based on the Actual Pressure Rate or Actual Force

Rate at the time this command is issued.
This command is especially designed for transitioning from position or velocity control to

pressure or force control while the axis is moving.

792

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: