E index (z) input, B wire break – Delta RMC151 User Manual

Page 905

Advertising
background image

9 Register Reference

the RMC70 QAx and Q1 and RMC150 UI/O

modules.
0=No break
1=Break Detected
In the Axis Tools, the A Input status bit and

the A Wire Break are combined into one cell

with the values On, Off, or Break.

2

BIn

B Input

Indicates the state of the quadrature input

(0=Off, 1=On). Available on all axes with

quadrature inputs.
This status bit is valid only if the B Wire

Break bit is off.
The Input and the Wire Break are

combined into one tag name, BIn, as

described below. In the Axis Tools, these are

represented as On, Off, or Break.

B

Wire

Break

(bit

1)

B

Input

(bit

0)

Value

of

BIn

Tag

Description

0

0

0

B Input On

0

1

1

B Input Off

1

0

2

Wire Break

Detected

1

1

3

Wire Break

Detected

All tab:

Feedback

3

B Wire Break

Indicates whether a broken wire is detected

on the quadrature B input. Available only on

the RMC70 QAx and Q1 and RMC150 UI/O

modules.
0=No break
1=Break Detected
In the Axis Tools, the B Input status bit and

the B Wire Break are combined into one cell

with the values On, Off, or Break.

All tab:

Feedback

4

ZIn

Index (Z) Input

Indicates the state of the Index (Z) input

(0=Off, 1=On). Available only on the RMC70

QAx and RMC150 Quadrature (Q) and

Resolver (R) modules. The status of this bit

is valid only if the Index (Z) Wire Break bit is

off.
The index (Z) Input and the Index (Z) Wire

Break are combined into one tag name, ZIn,

as described below. In the Axis Tools, these

are represented as On, Off, or Break.
The Index (Z) input is used for Homing.

All tab:

Home

deltamotion.com

885

Advertising
This manual is related to the following products: