Custom feedback auto-fault mode – Delta RMC151 User Manual

Page 963

Advertising
background image

9 Register Reference

How to Find: See individual parameters listed below

Data Type: DWORD - see below

Description

The Custom Feedback Configuration Register contains the bit-addressable Custom

Feedback configuration parameters. This topic lists the bit address for each parameter.

Each parameter is accessible in RMCTools via the Axis Parameter Editor. For details on

each parameter, see the respective links.

Tag Names

This register contains the following parameters. The tag names and bits for each are

given below.

Parameter

Tag

Bit(s)

Custom Feedback Auto-Fault Mode

AutoFault

0-3

For details on the values that each bit represents, see the respective parameter topic.

9.2.2.2.24.2. Custom Feedback Auto-Fault Mode

Type: Axis Parameter Register Bit Parameter

RMC70 Address: Primary Input: %MDn.8/0-3, where n = 12+ the axis number

Secondary Input: %MDn.26/0-3, where n = 12+ the axis number

RMC150 Address: Secondary Input: %MDn.8/0-3, where n = 24+ the axis number

Primary Input: %MDn.26/0-3, where n = 24+ the axis number

System Tag: Secondary Input: _Axis[n].CustomFBConfig.AutoFault

Primary Input: _Axis[n].SecCustomFBConfig.AutoFault
where n is the axis number

How to Find: Axes Parameters Pane, Setup tab: Feedback

Data Type: Bits - see below

Range: Missed Update (0), PROGRAM Mode (1), Disabled (2)

Default Value: Missed Update (0)

Description

This parameter is valid only on axes with custom feedback on the primary and/or

secondary input. This parameter provides options to automatically set the No Transducer

or Prs/Frc No Transducer error bit. The following options are available:

Missed Update

If the Custom Counts register is not written to in a given loop time, the No

Transducer error will be set. This is the preferred mode for most applications. In

this mode, you should make sure that the Custom Counts register is written to each

loop time.

PROGRAM Mode

If the controller is in PROGRAM mode, the No Transducer error will be set. This

mode may be useful in situations where you do not need to update the Custom

Counts very often, but you do wish to halt the axis if the program that updates the

Custom Counts is stopped due to the controller entering PROGRAM mode.

Disabled

The No Transducer error will not be set by any of the above options. In this mode,

the updating of the Custom Counts register is not monitored in any way. This could

deltamotion.com

943

Advertising
This manual is related to the following products: