Altera PowerPlay Early Power Estimator User Manual

Page 10

Advertising
background image

• Airflow

• Custom θ

SA

or Custom θ

JA

• Board thermal model
The ambient or junction temperature, heat sink, airflow, Custom θ

SA

or Custom θ

JA

, and board thermal

model parameters are optional. For more information about these parameters, refer to the Main

worksheet.
The clock frequency (f

MAX

) values imported into the PowerPlay EPE spreadsheet are the same as the f

MAX

values taken from the Quartus II software as per the design. You can manually edit the f

MAX

values and

the toggle percentage in the PowerPlay EPE spreadsheet to suit your design requirements.
To import data into the PowerPlay EPE spreadsheet, follow these steps:
1. In the PowerPlay EPE spreadsheet, Click Import CSV.

2. Browse to a PowerPlay EPE file generated from the Quartus II software and click Open. The file has a

name of <revision name>

_early_pwr.csv

.

3. In the confirmation window to proceed, click OK.

4. If the file is imported, click OK. Clicking OK acknowledges the import is complete. If there are any

errors during the import, an

.err

file is generated with details.

Related Information

Main Worksheet

on page 3-1

Estimating Power Consumption After Completing the FPGA Design

If your design is complete, Altera strongly recommends using the PowerPlay Power Analyzer in the

Quartus II software. The PowerPlay Power Analyzer provides the most accurate estimate of device power

consumption. To determine power consumption, the PowerPlay Power Analyzer uses simulation, user

mode, and default toggle rate assignments, in addition to placement-and-routing information.

Related Information

PowerPlay Power Analysis chapter in volume 3 of the Quartus II Handbook

UG-01070

2015.01.20

Estimating Power Consumption After Completing the FPGA Design

2-5

Setting Up the PowerPlay Early Power Estimator

Altera Corporation

Send Feedback