Altera PowerPlay Early Power Estimator User Manual

Page 14

Advertising
background image

Input Parameter

Description

Junction Temp, T

J

(°C)

Enter the junction temperature of the device. This field is only

available if you turn on the User Entered T

J

option. In this case,

the junction temperature is not calculated based on the thermal

information provided.
For Enpirion power device selection, Altera recommends setting

Junction Temp, T

J

(°C) to the highest value for the chosen

temperature grade.

Ambient Temp, T

A

(°C)

Enter the air temperature near the device. This value can range

from –40°C to 125°C. This field is only available when you turn

on the Auto Computed T

J

option.

If you turn on the Estimated Theta J

A

option, this field is used to

compute the junction temperature based on power dissipation and

thermal resistance through the top-side cooling solution (heat sink

or none) and board (if applicable).
If you turn on the Custom Theta J

A

option, this field is used to

compute junction temperature based on power dissipation and

custom θ

JA

entered.

Heat Sink

Select the heat sink that is used. You can select one of the

following:
• No heat sink (None)

• A custom solution (Custom)

• A heat sink with set parameters (15 mm–Low Profile, 23 mm–

Medium Profile, or 28 mm–High Profile). This field is only

available if you turn on the Auto Computed T

J

and Estimated

Theta J

A

options.

If you select None, the heat sink selection updates the custom θ

SA

value and you can see the value in the Custom θ

SA

(°C/W)

parameter. If you select Custom, the value is what is entered in the

Custom θ

SA

(°C/W) parameter.

Representative examples of heat sinks are provided. Larger heat

sinks provide lower thermal resistance and lower the junction

temperature. If the heat sink is known, consult the heat sink

datasheet and enter a custom θ

SA

value according to the airflow in

your system.

Airflow

Select an available ambient airflow in linear-feet per minute (lfm)

or meters per second (m/s). The values are 100 lfm (0.5 m/s), 200

lfm (1.0 m/s), 400 lfm (2.0 m/s), or Still Air. This field is only

available if you turn on the Auto Computed T

J

and Estimated

Theta J

A

options.

Increased airflow results in a lower case-to-air thermal resistance

and lowers the junction temperature.

3-4

Input Parameter

UG-01070

2015.01.20

Altera Corporation

PowerPlay Early Power Estimator Worksheets