Heat sink, Heat sink -4, Θja top = θjc+ θcs + θsa – Altera PowerPlay Early Power Estimator User Manual

Page 56

Advertising
background image

Figure 4-6: Temperature Variances

FAN

1

2

3

4

FPGA

For example, location 3 is where the ambient temperature pertaining to the device should be obtained for

input into the PowerPlay EPE spreadsheet. Locations 1 and 2 are cooler than location 3 and location 4 is

likely close to 25 °C if the ambient temperature outside the box is 25 °C. Temperatures close to devices in

a system are often in the neighborhood of 50–60 °C but the values can vary significantly. To obtain

accurate power estimates from the PowerPlay EPE spreadsheet, you must get a realistic estimate of the

ambient temperature near the FPGA device.

Heat Sink

The following equations show how to determine power when using a heat sink.

Figure 4-7: Total Power

Figure 4-8: Junction–to–Ambient Thermal Resistance

θJA TOP = θJC+ θCS + θSA

You can obtain the θ

JC

value that is specific to the FPGA from the data sheet. The θ

CS

value refers to the

material that binds the heat sink to the FPGA and is approximated to be 0.1 °C/W. You can obtain the θ

SA

value from the manufacturer of the heat sink. Ensure that you obtain this value for the right conditions for

the FPGA which include analyzing the correct heat sink information at the appropriate airflow at the

device.

4-4

Heat Sink

UG-01070

2015.01.20

Altera Corporation

Factors Affecting the PowerPlay Early Power Estimator Spreadsheet Accuracy

Send Feedback