Logic worksheet, Logic worksheet -13 – Altera PowerPlay Early Power Estimator User Manual
Page 23
Advertising
The total power is calculated based on the total θ
JA
value, ambient, and junction temperatures with the
following equation.
Figure 3-12: Total Power
Logic Worksheet
Each row in the Logic worksheet of the PowerPlay EPE spreadsheet represents a separate design module.
Enter the following parameters for each design module:
• Number of combinational adaptive look-up tables (ALUTs)
• Number of flipflops
• Clock frequency in MHz
• Toggle percentage
• Average fanout
Figure 3-13: Logic Worksheet of the PowerPlay EPE Spreadsheet
UG-01070
2015.01.20
Logic Worksheet
3-13
PowerPlay Early Power Estimator Worksheets
Altera Corporation