Logic worksheet, Logic worksheet -13 – Altera PowerPlay Early Power Estimator User Manual

Page 23

Advertising
background image

The total power is calculated based on the total θ

JA

value, ambient, and junction temperatures with the

following equation.

Figure 3-12: Total Power

Logic Worksheet

Each row in the Logic worksheet of the PowerPlay EPE spreadsheet represents a separate design module.

Enter the following parameters for each design module:
• Number of combinational adaptive look-up tables (ALUTs)

• Number of flipflops

• Clock frequency in MHz

• Toggle percentage

• Average fanout

Figure 3-13: Logic Worksheet of the PowerPlay EPE Spreadsheet

UG-01070

2015.01.20

Logic Worksheet

3-13

PowerPlay Early Power Estimator Worksheets

Altera Corporation

Send Feedback