Altera PowerPlay Early Power Estimator User Manual

Page 40

Advertising
background image

Figure 3-22: HSDI Worksheet of the PowerPlay EPE Spreadsheet

Table 3-12: HSDI Worksheet Information

Column Heading

Description

TX/RX Module

Specify a name for the module in this column. This is an

optional value.

Data Rate (Mbps)

Enter the maximum data rate in Mbps of the receiver or

transmitter module.

# of Channels

Enter the number of receiver and transmitter channels

running at the above data rate. This number must be an

integer value from 0 to 156.

Serialization Factor/ Deserialization Factor

Enter the number of parallel data bits for each serial data

bit. This number must be an integer value from 1 to 10.

Toggle %

Enter the average percentage of toggling on each clock

cycle. The toggle percentage ranges from 0 to 100%. The

default toggle percentage is 50%.

3-30

HSDI Worksheet

UG-01070

2015.01.20

Altera Corporation

PowerPlay Early Power Estimator Worksheets

Send Feedback

Advertising