Power model status for supported device families – Altera PowerPlay Early Power Estimator User Manual

Page 5

Advertising
background image

Power Model Status for Supported Device Families

The power models in the PowerPlay EPE spreadsheet are either in preliminary or final status. Preliminary

power models are subject to change. Preliminary power models are created based on simulation results,

process data, and other known parameters. The final power models are created based on a complete

correlation to the production device. If the power models are final, there are no further changes to the

power models. The power model status for the device will be shown in the Main worksheet of the

PowerPlay EPE spreadsheet.
For the majority of the designs, the PowerPlay Power Analyzer and the PowerPlay EPE spreadsheet have

the following accuracy after the power models are final:
• PowerPlay Power Analyzer: ± 20% from silicon, assuming that PowerPlay Power Analyzer uses the

Value Change Dump File (

.vcd

) generated toggle rates

• PowerPlay EPE spreadsheet: ± 30% from silicon, assuming PowerPlay EPE data imported from

PowerPlay Power Analyzer results using

.vcd

generated toggle rates

The toggle rates are derived using the PowerPlay Power Analyzer with a

.vcd

file generated from a gate

level simulation representative of the system operation.

Related Information

PowerPlay Early Power Estimators (EPE) and Power Analyzer

1-2

Power Model Status for Supported Device Families

UG-01070

2015.01.20

Altera Corporation

PowerPlay Early Power Estimator Overview

Send Feedback

Advertising