Report worksheet, Static power and dynamic current per voltage rail, Power up current – Altera PowerPlay Early Power Estimator User Manual

Page 49: Report worksheet -39, Power up current -39

Advertising
background image

Module

Parameters

Description

SDRAM

Frequency

Enter the operating frequency of the selected DDR protocol

used.

Type

Select the DDR protocol used.

Data Width

Select the width of the data lines (in bits).

Peripherals

Usage

Select On for module in use. Turn on the appropriate voltage for

one of the I/O banks before selecting the module.

Voltage

Select the voltage used for this module.

Report Worksheet

The Report worksheet shows all the information and power estimation results from the PowerPlay EPE

spreadsheet. You can find the power supply recommendations in the Power Supply Current (A) section,

which describes all the power supply requirements for the device that your design uses in the Min Current

Requirement (A) and the User Mode Current Requirement (A) columns.
The Min Current Requirement (A) column is not available for MAX 10 devices.

Static Power and Dynamic Current per Voltage Rail

The Report worksheet shows all the information and power estimation results from the PowerPlay EPE

spreadsheet. You can find the power supply recommendations in the Power Supply Current (A) section,

which describes all the power supply requirements for the device that your design uses in the Min Current

Requirement (A) and the User Mode Current Requirement (A) columns.

Figure 3-27: Separate Static and Dynamic Current in Power Supply Current Section

Power Up Current

In some device families, the power up current can be larger than the dynamic current required in the I/O

worksheet. For example, in Stratix III and Stratix IV devices, the I

CCPD

value on the I/O worksheet is

different than the Minimum current requirement for I

CCPD

in Report worksheet.

Altera provides the minimum current required for the V

CCPD

power rail for each voltage supply used, but

is not dependent on how many banks use that voltage supply.
To estimate the power up current, use the Report worksheet and compare the minimum current require‐

ment with user mode current requirement.

UG-01070

2015.01.20

Report Worksheet

3-39

PowerPlay Early Power Estimator Worksheets

Altera Corporation

Send Feedback

Advertising