Thermal analysis, Thermal analysis -9 – Altera PowerPlay Early Power Estimator User Manual

Page 19

Advertising
background image

Enpirion Worksheet

on page 3-40

Thermal Analysis

The following figure shows the Thermal Analysis section in the Main worksheet, including the junction

temperature (T

J

), total junction-to-ambient thermal resistance (θ

JA

), and the maximum allowed ambient

temperature (T

A

) values. For details about the values of the thermal parameters not listed in this user

guide, click the Details button.

Figure 3-5: Thermal Analysis Section of the PowerPlay EPE Spreadsheet

Table 3-3: Thermal Analysis Section Information

Column Heading

Description

Junction Temp, T

J

(°C)

The device junction temperature estimation based on

supplied thermal parameters.
The junction temperature is determined by dissipating the

total thermal power through the top of the chip and through

the board (if selected). For detailed calculations, click the

Details button.

θ

JA

Junction-Ambient

The junction-to-ambient thermal resistance between the

device and ambient air (in °C/W).
Represents the increase in temperature between ambient and

junction for every W of additional power dissipation.

Maximum Allowed T

A

(°C)

A guideline for the maximum ambient temperature (in °C)

that you can subject the device to without violating the

maximum junction temperature, based on the supplied

cooling solution and device temperature grade.

You can directly enter or automatically compute the junction temperature based on the information

provided. To enter the junction temperature, select User Entered T

J

in the Input Parameters section. To

automatically compute the junction temperature, select Auto Computed T

J

in the Input Parameters

section.
When automatically computing the junction temperature, the ambient temperature, airflow, heat sink

solution, and board thermal model of the device determine the junction temperature in °C. Junction

UG-01070

2015.01.20

Thermal Analysis

3-9

PowerPlay Early Power Estimator Worksheets

Altera Corporation

Send Feedback

Advertising