information from the <revision name>

_early_pwr.csv

into the PowerPlay EPE spreadsheet, you can edit the

PowerPlay EPE spreadsheet to reflect the device resource estimates for your final design.

Table 2-2: Advantages and Constraints of Power Estimation if your FPGA Design is Partially Complete

Advantage

Constraint

• You can perform power estimation early in the

FPGA design cycle.

• Provides the flexibility to automatically fill in the

PowerPlay Early Power Estimator spreadsheet

based on the Quartus II software compilation

results.

• Accuracy depends on your inputs and your

estimation of the device resources; where this

information may change (during or after your

design is complete), your power estimation

results may be less accurate.

• The PowerPlay EPE spreadsheet uses averages

and not the actual design implementation

details; for example ALUT input usage and

routing. The PowerPlay Power Analyzer has

access to the full design details.

Importing a File

To estimate power consumption with the PowerPlay EPE spreadsheet if your FPGA design is partially

complete, you can import a file.
Importing a file saves you time and effort otherwise spent on manually entering information into the

PowerPlay EPE. You can also manually change any of the values after importing a file.

Generate the PowerPlay EPE File

To generate the PowerPlay EPE file, follow these steps:
1. Compile the partial FPGA design in the Quartus II software.

2. On the Project menu, click Generate PowerPlay Early Power Estimator File to generate the <revision

name>

_early_pwr.csv

in the Quartus II software.

Import Data into the PowerPlay EPE Spreadsheet

You must import the PowerPlay EPE file into the PowerPlay EPE spreadsheet before modifying any

information in the PowerPlay EPE spreadsheet. Also, you must verify all your information after importing

a file.
Importing a file from the Quartus II software populates all input values on the Main worksheet that were

specified in the Quartus II software. These parameters include:
• Family

• Device

• Package

• Temperature grade

• Power characteristics

• Core voltage (V)

• Ambient (T

A

) or junction (T

J

) temperature (°C)

• Heat sink

2-4

Importing a File

UG-01070

2015.01.20

Altera Corporation

Setting Up the PowerPlay Early Power Estimator

Send Feedback