Figure 3-3: Power Tree Design Section in the Main Worksheet

Select a valid configuration from the Power Rail Configuration dropdown. When the Input Parameters

and Power Rail Configuration selections are complete, the power regulator selection will be enabled.
The current values shown for each regulator include the margin for regulator selection purpose. For more

information, refer to the Enpirion worksheet.
Errors regarding improper rail grouping may appear in the error window on the Main worksheet when

the Power Rail Configuration is selected. The following figure shows an example of the error message in

the error window.

Figure 3-4: Error Window in the Main Worksheet

This occurs when the EPE assigns rails with different voltage requirements to the same group. Since each

group is supplied by a single regulator, these errors must be corrected before the EPE can make proper

component selections. This is done in the EPE Report worksheet. Refer to the Report worksheet on how

to correct the error.

Related Information

Report Worksheet

on page 3-39

3-8

Power Tree Design