Features, Standards, Technical features – CIRCUTOR CVMk2 Series User Manual

Page 144: Standards 10.2. technical features, Technical features 10.1. standards

Advertising
background image

144

CVM

k2

MAINTENANCE / CALIBRA

TION

10. FEATURES

10.2. TECHNICAL FEATURES

10.1. STANDARDS

- CE Marking

- CAT III - 300 / 520 Vac in accordance with EN-61010 Standard.

- Protected against electrical shock by class II double insulation.

- Mounted on the DIN 46227 rail in accordance with EN50022 Standard.

- Energy accuracy according IEC 62053-22

VOLTAGE INPUTS

Minimum measurable voltage

10 V a.c

Measuring range

from 5 to 120% of Un for Un = 300 V a.c. (f-N)
from 5 to 120% of Un for Un = 520 V a.c (f-f)

Frequency

45…65 Hz

Maximum measured voltage

360 Vac

Acceptable overvoltage

750 Vac

Consumption

< 0.6 V•A

CURRENT INPUTS

Minimum measurable current

40 mA

Measuring range

from 1 to 120% of In for In = 5 A

Secondary for the TCs (In)

1 or 5 A

Primary current measured

Programmable < 30.000 A

Acceptable overload

6 A continuous, 100 A t<1 s

Consumption for (.../5 and .../1)

< 0.45 V•A

AUXILIARY POWER SUPPLY

Power supply

85 to 265 Vac (50-60 Hz) (consumption < 30 V·A)
100 to 300 Vdc (consumption < 25 W)

DIGITAL INPUTS

Use voltage

24 V d.c. ± 20%

Minimum signal width

40 ms

Consumption (each input)

< 0.5 W

DIGITAL PULSE OUTPUTS

Type:

Optocoupler

Voltage

150 VDC / 250 VAC

Current

100 mA

Maximum power (per output)

0.8 W

Máximum R

on

35 Ω

RELAY OUTPUTS

Nominal Voltage

230 VAC / 125 VDC

Nominal Current

6 AAC / 1,5 ADC

Máximum load VAC

250 VAC / 6 AAC

Máximum load VDC

30 VDC / 6 ADC

Mínimum load

1 VAC / 1mA

ANALOGUE OUTPUT

Scale

from 0 …. 20 mA or 4 ... 20 mA

Maximum acceptable charge

300 Ω

Response time

< 2 s