Adept Lynx Platform User Manual

Page 56

Advertising
background image

Adept Lynx Platform User's Guide, Rev B

Page 56 of 116

Chapter 5: Connectivity

Pin No.

Designation

Notes

3

LIGHT_P2

4

VBAT_IO_OUT4 VBAT @ 0.5A Max (shared with DIO)

5

LIGHT_P3

6

LIGHT_P4

NOTE: Light 4 is the buzzer on the light tower.

User Interface

Connector type

Mini-Fit

®

7 x 2

Use

Brake release, ON, OFF, E-Stop

Pin No.

Designation

Notes

1, 2, 3

FBAT_ALWAYS

Fused VBAT @ 500 mA

4

ESTOP_USR_1L

Short 4 & 11 to close ESTOP_USR_1

5

ESTOP_USR_2L

Short 5 & 12 to close ESTOP_USR_2

6

ESTOP_OUT_1L

Pins 6 & 13 short when ESTOP_CH1 is closed

7

ESTOP_OUT_2L

Pins 7 & 14 short when ESTOP_CH2 is closed

8

OFF_BUTTON

Short to FBAT_ALWAYS to signal OFF (min 1 s pulse)

9

START_BUTTON

Short to FBAT_ALWAYS to signal ON (min 1 s pulse)

10

MOTOR_BRAKE

Short to FBAT_ALWAYS for manual brake release

11

ESTOP_USR_1H Short 4 & 11 to close ESTOP_USR_1

12

ESTOP_USR_2H Short 5 & 12 to close ESTOP_USR_2

13

ESTOP_OUT_1H Pins 6 & 13 short when ESTOP_CH1 is closed

14

ESTOP_OUT_2H Pins 7 & 14 short when ESTOP_CH2 is closed

NOTE: An E-Stop jumper or a user-supplied E-Stop button needs to be attached to
the E-STOP port on the User Interface connector for the platform to function. The
jumper is provided as part number 12730-000L. An E-Stop button would be user-
supplied.