Commands execution, 1 overview, 2 generic commands – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (May 2014) User Manual

Page 49: 1 configure-error-strings, 1 overview 5.2 generic commands, Table 5-1, Configure-error-strings, Generic, Commands, Execution

Advertising
background image

Chapter 5

ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49C)

49

Commands Execution

5.1

Overview

CLI and XML are the primary ways to access ViewCheck capabilities on the blade. These
mechanisms allows you to perform activities such as start, stop and query on the ViewCheck
software. Using CLI and XML you can also set the parameters for monitoring.

Commands are classified into:

Generic commands

Commands for test management and control

Commands for monitoring

5.2

Generic Commands

Following are the general functional commands provided by the ViewCheck service.

5.2.1

configure-error-strings

configure-error-strings

command allows to add user-defined kernel error strings to

the diagnostics database.

Syntax for CLI
configure-error-strings errorStrings <string>

The following table provides the configure-error-strings command arguments.

The command syntaxes for XML interface is given for the diagnostic class with instance as
vee0. This instance varies depending on the blade.

Table 5-1 configure-error-strings

Argument

Data Type

Description

string

String

Kernel error string to be added to the diagnostics
database.

Advertising