Start-up

C.3.2 Compressed air connections

The compressed air connection is preinstalled on the
machine. It comprises the following components:

Pressure reducer

2 with manometer 4 and water

separator

5,

Pressure hose with push-in plug

1.

The pressure reducer is installed at the side mounting wall
of the worktable.

Connecting the machine to the compressed air sup-
ply system:
1. Connect pressure hose plug to on-site terminal unit.
2. Open on-site compressed air supply.
3. Set pressure reducer to a machine operating pressure

of 6 bar by rotating pressure reducer knob

3 and read

value on manometer

4:

• To increase pressure, rotate in clockwise direction.
• To reduce pressure, rotate in counter-clockwise di-

rection.

Fig. 3

Fig. 3