Short Seam Automat 2110-4 / 2111-4 Workinging Instructions

Beisler Automated Sewing Equipment

D.3

Programming

D.3.4 Global parameters

No.

Programmable global parameters (F2)

01

TILL CLAMP SIDEWAYS FWD:
After clam p backward, tim e until clam p m oves s ideways to folder / tim e interval

02

TILL CLAMP DOWN ......:
After clam p forward s ideways to piece pick-up, tim e until clam p down / tim e interval

03

TILL VACUUM OFF ......:
After clam p down, tim e until vacuum is s witched off / tim e interval

04

THRD LENGTH,BOBBIN FULL
Length of thread of filled bobbin

05

TILL CLAMP INSERTING:
Clam p ins ertion delay / tim e delay

06

SEWING END ->CL.SIDEW.:
After s ewing drive s tops , tim e until clam p m oves s ideways / tim e interval

07

TIME AFTER CLAMP OPEN :
After clam p s ideways , tim e until clam p opens / tim e interval
For m achines with s afety s witch:
After clam p rearward s ideways and ES5 s witches , tim e until clam p opens / tim e interval

10

TILL FOLDING CL. CLOSED:
After folder right and down, tim e until folding clam p clos es

11

TILL FOLDER LIFT UP...:
After folding clam p clos es , tim e until folder up / tim e interval

12

TILL FOLDER SWINGS LEFT:
After folder up, tim e until folder s wings left and rotates / tim e interval

13

IMPULS FOLDER DOWN ...:
Puls e duration folder down, tim e until folder is s witched airles s during pick-up / tim e delay

14

CL.OPEN TILL FOLDER UP:
After folding clam p opens , tim e until folder up / tim e interval

17

TILL TENSION OPEN ....:
After end of s eam , tim e until tens ion blower on / tim e interval

18

DURATION OF TENS. OPEN:
ON duration for tens ion blower

19

TILL THREAD CLAMP FORW.:
After clam p up, tim e until thread clam p forward / tim e interval

20

DUR.THREAD CLAMP FORW.:
Duration of blowing and thread clam p forward

21

TILL STACKER TRANSPORT:
After s ewing drive s tops and trans port s tam p down, tim e until s tacker trans port m oves backward to ES8 / tim e
interval

22

DUR.SLIDING TABLE OPEN:
Duration for s liding table open / tim e delay

23

LIFT.TABLE MOD 00/01-99:
Lower lift table, defaults :
Input 00: Lower lift table us ing photocell control
Input 01-99: Lift table is lowered after corres ponding num ber of pieces

24

DUR.LIFTING TABLE SINKS:
Lower lift table / duration

25

TILL FABRIC CLAMP FORW.:
After foots witch is releas ed, tim e until pocket bag clam p clos es / tim e interval