Slot Preamble Length

This menu item, which appears in all Hub and Remote configurations, displays

the current Slot Preamble size in milliseconds and bytes for the remotes in the

group. The Slot Preamble is the period between when the remote begins to

transmit (sends an ACK) to the Hub and when the first data packet is sent. This

allows time for signal lock to occur before data is sent, thus preventing data

loss. Higher data rates allow for a shorter preamble, since it is easier to achieve

signal lock. The setting for this parameter should be obtained using the Vipersat

STDMA Calculator.

Note: When either the BFAT feature is enabled or the Hub type is ECMv2, the

preamble length is set automatically for the unit.

On a Hub unit, entering P at the command prompt allows changing the pream-

ble duration in milliseconds.

Figure 3-17 Slot Preamble Length prompt

On Remote units, this menu item is an information-only display.

Slot Data Length

This menu item displays the Slot Data Length in milli-seconds and bytes for the

remotes in the group, and represents the amount of data that can be transmitted

or received in one spin of the STDMA cycle by each of the Remotes belonging

to that group. This is the amount of time that the remote is provided to send data

in the cycle.
Depending on the Hub type that is defined for the modem, the appearance of

this parameter will vary:

Fixed – Slot Data Length
Dynamic Slot – Nominal Data Length, Minimum Data Length
Dynamic Cycle – Maximum Data Length, Minimum Data Length
GIR – Minimum Data Length
Entry Channel – Data Length, Minimum Data Length