Percent Allocation

This menu item appears for Hub modems only.
The Percent Allocation menu item allows adding a fixed percentage to the

channel bandwidth request to accommodate additional bandwidth requirements

which may occur after the switch is made from STDMA to SCPC mode.
Typically the default value (10%) will be sufficient, but if there may be a larger

bandwidth requirement after the switch, the percent allocation value can be

increased. In choosing a value for this allocation, future bandwidth require-

ments for the channel must be balanced against efficient bandwidth utilization.
To change this setting, enter E at the command prompt in the Auto Switching

screen to display the dialog shown in figure 3-50.

Figure 3-50 Percent Allocation prompt

SCPC Step Up Threshold

This menu item appears for Remote modems only.
The SCPC Step Up Threshold establishes the percentage of bandwidth use

that will trigger a switch up from the present SCPC rate to a higher rate to

ensure that there is sufficient bandwidth available for current conditions.
A default value (95%) is provided, but if a different threshold is desired, an

alternate value can be specified by entering U at the command prompt in the

Auto Switching screen to display the dialog shown in figure 3-51. Note that

this value must be greater than the value specified for the SCPC Step Down

Threshold.