Vipersat Configuration

3-46

Vipersat CDM-570/570L User Guide

• Enter Name for TOS ID [ ] - At the prompt, enter a user-defined text

label for circuit identification.

• Enter the TOS ID - Enter an integer value in the range of 1 to 63.

Entering a value of 0 will result in no switch.

• Enter the Switch Type - Enter an integer value in the range of 64 to 254

at the prompt to inform the VMS what switching policy to use. Entering a

value of 0 will result in no switch.

• Enter the TOS SCPC Switch Data Rate - Enter the desired data rate for

this service type. Valid entries are from 0 to 10,000 Kbps. This setting will

override the VMS set policy value.

• Enter the TOS SCPC Timeout - This timer monitors the defined packet

flow. Once data stops for the duration of the timer setting, the link state

will be restored to the home state condition. Valid entries are from 1 to 60

seconds.

After entering the timeout value, pressing the Enter key will update the TOS

Switching Control menu with the changes.

Max Streams

The maximum number of simultaneous ToS switched sessions for a Remote can

be specified by entering M at the command prompt in the ToS Switching

Control screen. Valid range is from 1 to 127.

Figure 3-60 ToS Max Streams prompt

Delete

Enter D at the command prompt in figure 3-58 to Delete a ToS entry, as shown

in figure 3-61.

Figure 3-61 ToS Delete prompt

Advertising