Primary Heart Beat

This menu item appears for the Hub modem only.
The Primary Heart Beat feature is a redundancy heart beat message for

primary Hub units that provides the option for a periodic communications check

message to be sent from the Hub modem to the VMS for backup recovery in

N:M redundancy (protected) configurations. The message interval is hard-coded

in the modem.
Enter P at the command prompt in the Vipersat Configuration screen

(figure 3-6) to toggle this feature between Enabled and Disabled.

Home State Revert

This menu item appears for the Remote modem only.
The Home State Revert feature allows automatic resource recovery to be

performed on SCPC connections when a communications failure occurs

between the VMS and a Remote, such as a rain fade condition, a Remote unit

power down, or a hardware failure. The period of time (in minutes) for a failure

is configured in the VMS for each Remote in the network. Should communica-

tions be lost for more than the specified time period, the Remote will automati-

cally revert to its Home State settings and the VMS will remove all allocated

resources (bandwidth, demod(s)), freeing them for use by any other Remote in

the Vipersat network.
Because this feature is configured in the VMS, the status (Disabled, or the Time

Period in minutes) appears as an information-only display in the Vipersat

Configuration menu (figure 3-6).

Dynamic Power Control Configuration

Dynamic Power Control (DPC) is a Vipersat feature that acts to regulate the

transmit power of the Vipersat satellite modem, such that the specified receive

signal level (Eb/No) is met for the receiving Vipersat units in the group. DPC is

driven by the receiver demod, which notifies the transmitting modem of the

current Eb/No value.
Refer to Appendix C, “Dynamic Power Control,” in this document for addi-

tional information on the DPC feature.
The Dynamic Power Control Configuration screen (enter C in the Vipersat

Configuration menu) allows for setting the parameters for the CDM-570/570L