Chapter

3 -

Using the Command Line Interface (CLI)

3-23

Vipersat Configuration

Figure 3-23 STDMA Remote Policies screen (GIR Hub)

Entering the Remote number at the command prompt in figure 3-23 allows the

Guaranteed Information Rate and the Automatic Load Switch Rate for that

Remote to be set, as shown in figure 3-24. Note that the Available Bandwidth is

displayed for reference in this screen to assist with entering the appropriate

rates. The cycle length for GIR is limited to a maximum of one second.

Figure 3-24 GIR Remote Policies prompt

Set the Automatic Load Switch Rate to a value greater than the GIR to allow the

Remote to be automatically switched out of STDMA and into SCPC mode

when traffic exceeds the GIR. A Switch Rate of 0 will prevent the Remote from

being switched out of STDMA and into SCPC mode.
The Remote Policies screen for an Entry Channel Hub type allows the SCPC

data rates and switch types to be specified for when the Remotes will switch and

the desired starting points for communications.