Printer Commands

Chapter 6

44

322M Operator’s Manual

^A

^D

COMMAND

21

Change SW1: Software DIP Switch #1. The DIP switch commands may use

either the ^A(decimal) or ^AB(binary) value. Since each bit represents a setting for
the printer, the soft switches are always reported in binary.

For example: ^AB10100001^D21<CR> configures serial port #1 for text equivalent
enquiry responses, accept control codes, disables echo, and enables XON/XOFF
flow control.

^AB12345678 (each bit is represented by a numeric position number)

Position:

1,2

Enquiry Response: This determines what the printer will send back in
response to an enquiry command.

00 = Control Codes

10 = Text Equivalent

11 = ^ Equivalent


3

Control Codes:

This position is used to set the printer’s handling of

control codes.

1 = Ignore Control Codes

0 = Accept Control Codes


4

Port #1 Parity Selection: Sets the printer port #1 parity for serial
communication.

1 = Odd Parity

0 = Even Parity


5

Port #1 Parity Enable:

Sets the printer’s port #1 parity enable for serial

communication.

1 = No Parity

0 = Enable Parity


6

Echo: If this feature is enabled, the printer will echo all received
characters to the serial port.

1 = Enable

0 = Disable


7

Port #1 Data Bits:

Sets the printer’s port #1 data bits for serial

communication.

1 = 8 Data Bits

0 = 7 Data Bits


8

XON/XOFF Flow Control: Sets software flow control handshaking.
CTS/RTS hardware handshaking is always enabled.

1 = Enable

0 = Disable