Microcom 322M User Manual

Page 50

Advertising
background image

Printer Commands

Chapter 6

46

322M Operator’s Manual

110 = Rom or Saved Format File 6

111 = ROM of Saved Format File 7



^A

^D

COMMAND

23

Change SW3: Software DIP Switch #3. The DIP switch commands may use

either the ^A(decimal) or ^AB(binary) value. Since each bit represents a setting for
the printer, the soft switches are always reported in binary.

^AB12345678 (each bit is represented by a numeric position number)

Position:

1

Extended ASCII: If enabled, characters over HEX 7F will be
processed.

1 = Disable

0 = Enable

2

Invert >INPUT 1< Polarity: The >INPUT 1< message is normally
returned when the associated reflective sensor detects a signal. The
polarity of this signal should be inverted when used as a stock level
sensor.


3

Response After Print: If enabled, an enquiry response will be sent
through the serial communications port #1 (COM1) after every print.

1 = Enable

0 = Disable


4

Head Up Switch: Sets the state of the Head Up Switch. Not available
on the Model 322M printer.

1 = Enable

0 = Disable


5

ALWAYS 0


6

ALWAYS 0


7

Binary Compression: If enabled, the printer will accept downloaded
binary compressed font and/or graphic files. Enquiry responses are
generated by sending 5 NULL characters when binary compression is
enabled

1 = Enable

0 = Disable


8

Detect Black Line on Power-up: If enabled, the printer automatically
feeds labels on power-up to determine the proper ^D91 value.

1 = Enable

0 = Disable



Advertising