Chapter 9

Bar Codes

322M Operator’s Manual

75

A..A, B..B, C..C, etc. are variable-length alphanumeric fields separated by #1d. These fields
are optional according to the MaxiCode specification, but may be required by some
applications.

Format 2
PPPPPPPPP#1dCCC#1dSSS#1dA..A#1dB..B#1dC..C#04


The individual fields are the same as previously described in Format 1.

Mode 3:
Mode 3 may have either of the following formats:
Format 1

[)>#1e01#1dYYPPPPPP#1dCCC#1dA..A#1dB..B#1dC..C#1e#04

Format 2

PPPPPP#1dCCC#1dSSS#1dA..A#1dB..B#1dC..C#04

Where:
#1e is the ASCII RS character
#1d is the ASCII GS character
#04 is the ASCII EOT character
YY is the two digit numeric year
PPPPPP is the six character alphanumeric Postal Code.
CCC is the three digit numeric Country Code
SSS is the three digit numeric Class of Service
A..A, B..B, C..C, etc. are variable length alphanumeric field separated by the #1d. These
fields are optional according to the MaxiCode specification, but may be required in certain
application.

Mode 4:
Mode 4 may encode any string of up to 93 characters. Control characters are specified in
Table 15, and occupy only one character in the encoded string.

Mode 5:
Mode 5 may encode any string of up to 77 characters. Control characters are specified in
Table 15, and occupy only one character in the encoded string.

Mode 6:
Mode 6 may encode ant string up to 93 characters. Control characters are specified in
Table 15, and occupy only one character in the encoded string.