Sensor – OpenEye E-Series Slim User Manual

Page 44

Advertising
background image

44

Sensor Setup

1.

Set the Sensor

TYPE

to

N/O

(Normally Open) or

N/C

(Normally Closed).

2.

Repeat for all sensors.

3.

Click

SAVE.

Alarm Setup

1.

Enable or disable the

SIGNAL

(

ON / OFF

).

2.

Set each alarm

TYPE

(

NO / NC

).

3.

Repeat for all relays.

4.

Click

SAVE

.

Power Off

The

POWER OFF

option is a preset function that triggers an alarm relay when the recorder

loses power. This function is preconfigured to set alarm relay No. 1 to

ON

and

N/C

. When a

power loss occurs, alarm relay No. 4 will open. When power is restored the alarm will close.

S.M.A.R.T. Alarm

The

S.M.A.R.T. ALARM

option is a preset function that triggers an alarm relay when the

HDD exceeds the temperature threshold configured on the

SYSTEM > DISK SETUP >

S.M.A.R.T.

page. This function is preconfigured to set an alarm relay to

ON

and

N/C

. When

the HDD exceeds the temperature threshold, the alarm relay will open. When the temperature
is at a safe level again the alarm will close.

SET

and

CLEAR

are used to test the alarm relay operation.

SET

is used to

manually activate all relays that are set to

ON

.

CLEAR

is used to manually

deactivate all relays.

Hold Video Loss

When set, the alarm will stay on when a channel loses video. The alarm will turn off when
Video returns.

Advertising
This manual is related to the following products: