RC4000 Antenna Controller

Chapter 2

Hardware

28

2.1.2.3.4 J4 - Relay

J4 "NO NC COM" 3 pin Type 2

HPA Disable, normally-open, 3A @ 30VDC max or 3A @ 250VAC max

HPA Disable, common, 3A @ 30VDC max or 3A @ 250VAC max

HPA Disable, normally-closed, 3A @ 30VDC max or 3A @ 250VAC max

- typically HPA

The HPA disable is in a form-C contact arrangement with a normally-open, normally-closed and common
contacts. While the antenna is below the down elevation limit or while the antenna is performing any
large-scale auto-moves, such as deploy, locate, or stow, the normally-closed and common pins will be
connected. After the auto-move is complete, the connection will be released.

2.1.2.3.5 J5 - Bar LEDs

This connector is used by the RC300 product but not utilized for a RC4000 application.

2.1.2.3.6 J6 - Interboard Bus B

J6 "none" 40 pin Type 3

-- see 2.1.2.2.1 for pinouts

2.1.2.3.7 J7 - LEDs

This connector is used by the RC300 product but not utilized for a RC4000 application.