SSi Manual #4563 Rev. D Page 39 Multi-Gas Model 6000

2021

read SPI

2022

SPI data counter, high byte

2023

SPI store state 0 = normal operation (store)

1 = receiving data from boss, 2 = OK to send to Cell, 4 = sending to cell

2024

timer on SPI response, 10ms inc

2025

indicates

SPI

responded

2026

Last

command

used

2027

Result of the last command

* Registers 2028 to 2029 not used
* Data sent by IR cell in master mode

2030

decimal place //debug

2031

gas reading

* calc structure

2032

deg C (2032 - 2033)

2034

volts (2034 - 2035)

2036

atten (2036 - 2037)

2038

zero_volts_tc (2038 - 2039)

2040

span_volts_tc (2040 - 2041)

2042

atten_tc (2042 - 2043)

2044

curve_in (2044 - 2045)


* cal structure

2046

degCZ (2046 - 2047)

2048

degCS (2048 - 2049)

2050

Zero_volts (2050 - 2051)

2052

Span_Volts (2052 - 2053)

2054

ztc (2054 - 2055)

2056

stc (2056 - 2057)

2058

zero_offset (2058 - 2059)

2060

span_target (2060 - 2061)

2062

Command

2063

Command

result

* curve structure

2064

c_dummy (2064 - 2065)

2066

coeff_0 (2066 - 2067)

2068

coeff_1 (2068 - 2069)

2070

coeff_2 (2070 - 2071)

2072

coeff_3 (2072 - 2073)

2074

coeff_4 (2074 - 2075)

2076

coeff_5 (2076 - 2077)

2078

coeff_6 (2078 - 2079)

2080

coeff_7 (2080 - 2081)


* EEROM structure

2082

software revision (2082 - 2090)

* Define date_of_cal

2091

Filter

2092

span_offset (2092 - 2093)

* Registers 2094 to 2098 not used
* calculated values

2099

gas_value_adj

2100

copy of PIC_com_stat

2101