Part number designations, Electrical connections basic operating description – Super Systems MGA6000 User Manual

Page 5

Advertising
background image

SSi Manual #4563 Rev. D Page 5 Multi-Gas Model 6000

Part Number Designations


The following table references the gases available in the MGA6000s with their applicable part numbers.

Part

Number:

13404 13391 13392 13393 13394 13395 13396 13397 13398 13399 13402 13403

CO

X

X

X

X

X

X

X

X

CO2

X

X

X

X

X

X

CH4

X

X

X X X

H2

X

X X X X

X


Oxygen cell option: Part number 13400 will add Oxygen (O2) to the MGA.

Example: Part Number 13399 would contain: Carbon Monoxide (CO), Methane or Natural Gas (CH4), and

Hydrogen (H2).

Electrical Connections

Basic Operating Description

The Model MGA6000 has been designed for the simultaneous analysis of selected gases in heat-treat furnace

atmosphere gases. It has a 16 line by 40-character LCD display and a 4 x 4 keypad for the operator interface.

Information is presented to the operator on various screens. The operator selects the appropriate page and enters the

number using the keypad.

1001

+

1002

-

1003

GND

1101

+

1102

-

1103

GND

1211

+

1212

-

1221

+

1222

-

1231

+

1232

-

1241

+

1242

-

1301

+

1302

-

1411

+

1412

-

1421

+

1422

-

1501

+

1502

-

RS 485 COMMS

(AUTO-CAL BOX)

90-265 VAC

RS 485 COMMS

(MASTER)

4-20mA #1

4-20mA #2

4-20mA #3

4-20mA #4

Alarm/Control

Digital Input #1

(Pump Stop)

Digital Input #2

(Inhibit Adjustment)

Advertising