Chapter 2. Installation

Step-by-Step Installation Instructions

STEP 3 CONNECTING ENCODERS TO THE NETWORK AND

CONFIGURING STREAM SETTINGS

1. Using a Cat-5 cable, connect your SVSi Encoder’s P0 port to a PoE-enabled switch. In non-

PoE applications connect a 12V regulated power supply (N9312) to the two-pin terminal block
plug connector (labeled +12V 2A).

2. In N-Able, select the Unit Management tab and click the Auto Discover button (if the table

has not already populated itself with the installed units). See

Figure 2-6

.

Figure 2-6. Unit Management Page

3. Find your Encoder in the list. N2000 units are displayed on the following tabs:

Unit Management tab — N2000 units have N2000 Encoder/Decoder listed in their Type

fields.

Video Matrix tab — N2000 units are found on the N2000 sub-tab (as shown in

Figure 2-7

).

Note: In order for the unit to receive PoE, it must be connected to a switch or other equipment
that has a PoE PSE port.

Note: If using multiple Encoders in your set up, it is important to plug in and configure one
Encoder at a time. All Encoders come pre-configured to use stream 1. As you add Encoders
to the network, you will need to set them up to use different streams.