Figure 2-1 t, Figure 2-1 or, Hazardous area oxymitter 4000 – Emerson Process Management OXYMITTER 4000 User Manual

Page 48: Instruction manual

Advertising
background image

Instruction Manual

IB-106-340C Rev. 4.1
July 2004

2-2 Installation

Rosemount Analytical Inc. A Division of Emerson Process Management

Hazardous Area Oxymitter 4000

CO

VER REMO

V

A

L & A

CCESS

305

305

(12)

(12)

ADD

T

O DI

M

“A

FOR PR

OBE

W

IT

H

CERAMI

C DI

FFUSER

95 (

3

.8

)

WI

T

H

SNUBBER

DI

FFUSER

DI

M "

A

"

66 (2

.6

)

76 (3

.0

)

DI

M "

B

"

REMO

V

A

L ENVELOPE

ELEC CONN

3/

4 N

P

T

6 m

m

TU

BE

JI

S

ANSI

(

)

TUBE

6.

35

1/

4

D

IN

6

.35 (

1

/4

)

TUBE

CAL

GAS

REF AI

R

BO

TT

OM

VI

EW

P

S

U

E

I

T

P

I

C

R

H

W

E

N

T

H

G

C

KE

N

I

-

E

E

R

W

A

V I

S

O

L

P

-

X

O

M

T

A

G

NI

N

-

R

I

T

L

A

I

VE

-

E

E

H

343 (

13.

5)

GAS

CAL.

500

V

A

R

SERI

A

L NO

.

TA

G

N

O

.

O

XYM

IT

TER

4000

V

O

L

T

S:

W

A

TTS:

OUTPUT

:

L

IN

E FUSE:

Ros

e

m

ount

Ana

lyt

ic

al

I

n

c.

O

rr

v

il

le

,

O

H

44667-

0901

85-

264

V

A

C

48-

62 H

z

TM

8

0

0

-4

3

3

-6

0

7

6

4-

20 m

A

R

5 A

m

ps

TM

HAR

T

SM

AR

T F

A

M

IL

Y

REF

.

GAS

-

-

R

H

G

T

I

N

E

W

H

C

I

T

KE

P

E

A

IT

C

U

E

V

LI

-

M

N

IN

L

O

A

R

P

N

I

X E

-

W

G

E

S

IV

A

T

O

S

E

HE

R

P

167

(6

.58)

(2

.89)

73

(1

.55)

39

PR

OCESS FLO

W

MUST BE I

N

THI

S

DI

RECTI

O

N

W

ITH RESPECT

TO

D

E

F

L

E

C

T

O

R

3534B48G

01

IN

S

U

L

A

TE I

F

EXPOSED

TO

AMBI

ENT

W

E

A

T

HER CONDI

TI

ONS

THESE FLA

T F

A

CED FLANGES ARE

MANUF

A

C

TURED

T

O

ANSI

, DI

N,

& JI

S BOL

T

P

A

TTERNS;

AND ARE NO

T PRESSURE RA

TED

.

AL

L

DI

MENSI

O

NS ARE I

N

MI

L

L

IMETERS

W

IT

H

IN

C

H

E

S

IN

P

ARENTHESES UNLESS

O

T

HER

W

ISE NO

TED

.

NO

TES:

0.

062 I

N

.THK GASKET

C

E

R

T

IF

IC

A

T

IO

N

APPR

O

VED

LABEL

EXTERNAL

EAR

TH

EXTERNAL

EAR

TH

VENT

REF

.

AI

R

IN

TERNAL

EAR

TH

T

ABLE 1

MOUNTI

N

G FLANGE

(G

ASKET I

NCLUDED)

(4

) H

O

L

E

S

EQ SP

ON BC

HOL

E

DI

A

FLANGE

DI

A

DI

N

ANSI

152.

4

(6

.00)

190

(7

.5

)

19 (

.75)

170

(6

.69)

18 (

.71)

210

(8

.25)

T

ABLE 2 I

N

ST

ALLA

TI

ON/

R

EM

O

VA

L

DI

M "

A

"

3 FT

6 FT

PR

OBE

18 I

N

.

DI

M "

B

"

2174

(85.

6)

1831

(72.

1)

917

(36.

1)

1448

(57.

0)

803

(31.

6)

460

(18.

1)

35910002

Figure 2-1. Hazardous Area Oxymitter 4000 Probe Installation

Advertising