7 x21 dce, X21 dce – ATL Telecom AM200 User Manual

Page 129

Advertising
background image

ATL User Guide

AM200 Modem

129

13

13.8.7 X21 DCE

The X21DCE connection on the AM200 is supplied via a 25way male D Type to 15Way female D Type
Converter Cable. The cable plugs into the RS530 connector on the back of the AM200.

25 Way D Type Pin

Out

Name

CCT

15 Way D Type Pin

Out

1

Shield

101

1

2

Transmitted Data A

103

2

3

Received Data A

104

4

4

Request To Send A

105

3

5

Clear To Send A

106

6

Data Set Ready A

107

7

Ground

102

8

8

Data Carrier Detect A

109

5

9

Received Clock B

115

13

10

Data Carrier Detect B

109

12

11

External Transmitter Timing B

113

14

12

Transmitted Clock B

114

13

Clear To Send B

106

14

Transmitted Data B

103

9

15

Transmitted Clock A

114

16

Received Data B

104

11

17

Received Clock A

115

6

18

Local Loopback

141

19

Request To Send B

105

10

20

Data Terminal Ready A

108

21

Remote Loopback

140

22

Data Set Ready B

107

23

Data Terminal Ready B

108

24

External Transmitter Timing A

113

7

25

Test Mode

142

25 way Male D-Type

Pin 1

Pin 1

15 way Female D-Type

Advertising